Parameter
<NR2>
Current protection level.
Minimum: Depend on the unit type:
if Irated * 0.1 > 5A, then minimum = 5A,
else minimum = Irated * 0.1
Maximum: Irated * 1.1
MIN
Minimum current level.
MAX
Maximum current level.
Return parameter
<NR2>
Returns the current protection level.
Example
SOUR:CURR:PROT:LEV?
+5.000
Returns the minimum possible current level in
amps.
[:SOURce]:CURRent:PROTection:STATe
Set
Query
Description
Turns OCP (over-current protection) on or off.
Syntax
[:SOURce]:CURRent:PROTection:STATe
{<bool>|OFF|ON}
Query Syntax
[:SOURce]:CURRent:PROTection:STATe?
Parameter
OFF | 0
Turns the OCP off.
ON | 1
Turns the OCP on.
Return parameter
<bool>
Returns the over current protection state
in <bool> format.
Example
SOUR:CURR:PROT:STAT OFF
Turns OCP off.
[:SOURce]:CURRent:PROTection:TRIPped
Set
Query
Description
Returns the state of the current protection circuits.
Query Syntax
[:SOURce]:CURRent:PROTection:TRIPped?
Return parameter
<bool>
Returns protection status.

Table of Contents

Other manuals for GW Instek PSU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSU Series and is the answer not in the manual?

GW Instek PSU Series Specifications

General IconGeneral
BrandGW Instek
ModelPSU Series
CategoryPower Supply
LanguageEnglish

Related product manuals