PSU Series Programming Manual
90
Return
<NR1>
Returns the bit sum of the Operation
Condition register.
:STATus:OPERation:ENABle
Set
Query
Description
Sets or queries the bit sum of the Operation Status
Enable register.
Syntax
Query Syntax
:STATus:OPERation:ENABle <NR1>
:STATus:OPERation:ENABle?
Parameter
<NR1>
0~32767
Return parameter
<NR1>
0~32767
:STATus:OPERation:PTRansition
Set
Query
Description
Sets or queries the bit sum of the positive
transition filter of the Operation Status register.
Syntax
:STATus:OPERation:PTRansition <NR1>
:STATus:OPERation:PTRansition?
Parameter
<NR1>
0~32767
Return parameter
<NR1>
0~32767
:STATus:OPERation:NTRansition
Set
Query
Description
Sets or queries the bit sum of the negative
transition filter of the Operation Status register.
Syntax
Query Syntax
:STATus:OPERation:NTRansition <NR1>
:STATus:OPERation:NTRansition?
Parameter
<NR1>
0~32767
Return parameter
<NR1>
0~32767

Table of Contents

Other manuals for GW Instek PSU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSU Series and is the answer not in the manual?

GW Instek PSU Series Specifications

General IconGeneral
BrandGW Instek
ModelPSU Series
CategoryPower Supply
LanguageEnglish

Related product manuals