Return parameter
<bool>
Returns the key lock status.
:SYSTem:KEYLock:MODE
Set
Query
Description
Sets or queries the keylock mode. This setting is
the equivalent to the F-19 function setting.
Syntax
Query Syntax
:SYSTem:KEYLock {<bool>|OFF|ON}
:SYSTem:KEYLock?
Parameter/Return
parameter
0 | OFF
Panel lock: allow output off.
1 | ON
Panel lock: allow output on/off.
:SYSTem:ERRor:ENABle
Set
Query
Description
Clears the Error Queue and enables all error
messages to be placed in the System Error Queue.
Syntax
:SYSTem:ERRor:ENABle
:SYSTem:LANGuage:EMULation
Set
Query
Description
Sets or queries the command language.
Syntax
Query Syntax
:SYSTem:LANGuage:EMULation
{“NONE|N5700|GENSYS”|PWX”}
:SYSTem:LANGuage:EMULation?
Parameter/
Return parameter
NONE
Emulation is not used. This is the
default setting
N5700
N5700/N8700 emulation is used.
GENSYS”
GENESYS emulation is used.
PWX
PAG emulation is used.
:SYSTem:LANGuage:[:SELect]
Set
Query
Description
Sets or queries the command language.

Table of Contents

Other manuals for GW Instek PSU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSU Series and is the answer not in the manual?

GW Instek PSU Series Specifications

General IconGeneral
BrandGW Instek
ModelPSU Series
CategoryPower Supply
LanguageEnglish

Related product manuals