REMOTE CONTROL
77
:DISPlay[:WINDow]:TEXT[:DATA]
Set
Query
Description
Sets or queries the data text that will be written to
the display. Writing to the display will overwrite
data that is currently on the screen. Overwriting a
display area with a shorter string may or may not
overwrite the screen. The string must be enclosed
in quotes: “STRING”. Only ASCII characters 20H
to 7EH can be used in the <string>.
Syntax
Query Syntax
:DISPlay[:WINDow]:TEXT[:DATA] <string>
:DISPlay[:WINDow]:TEXT[:DATA]?
Parameter/
Return parameter
<string>
ASCII character 20H to 7EH can be used
to in the string parameter. The string
must be enclosed in quotes: “STRING
Example
DISP:WIND:TEXT:DATA “STRING”
Writes STRING to the display.
Query Example
DISP:WIND:TEXT:DATA?
“STRING”
Returns the text data string on the screen.
:DISPlay:BLINk
Set
Query
Description
Turns blink on or off for the display. Blink is set to
OFF by default.
Syntax
Query Syntax
:DISPlay:BLINk {<bool>|OFF|ON}
:DISPlay:BLINk?
Parameter
OFF | 0
Turns blink OFF
ON | 1
Turns blink ON
Return parameter
<bool>
Returns the blink status.
Example
DISP:BLIN 1
Turns blink ON.

Table of Contents

Other manuals for GW Instek PSU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSU Series and is the answer not in the manual?

GW Instek PSU Series Specifications

General IconGeneral
BrandGW Instek
ModelPSU Series
CategoryPower Supply
LanguageEnglish

Related product manuals