REMOTE CONTROL
153
Error Code
Description
-100 Command
Error
This is the generic syntax error for devices that
cannot detect more specific errors. This code
indicates only that a Command Error as defined in
IEEE 488.2,11.5.1.1.4 has occurred.
-102 Syntax error
An unrecognized command or data type was
encountered; for example, a string was received
when the device does not accept strings.
-103 Invalid
separator
The parser was expecting a separator and
encountered an illegal character; for example, the
semicolon was omitted after a program message
unit, MEAS:VOLT:DC?:MEASCURR:DC?
-104 Data type
error
The parser recognized a data element different
than one allowed; for example, numeric or string
data was expected but block data was
encountered.
-108 Parameter
not allowed
More parameters were received than expected for
the header; for example, the KLOCk command
only accepts one parameter, so receiving
SYSTem:KLOCk 1,0 is not allowed.
-109 Missing
parameter
Fewer parameters were recieved than required for
the header; for example, the KLOCk command
requires one parameter, so receiving KLOCk is not
allowed.
-111 Header
separator error
A character which is not a legal header separator
was encountered while parsing the header; for
example, no white space followed the header, thus
*SRE2 is an error.

Table of Contents

Other manuals for GW Instek PSU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSU Series and is the answer not in the manual?

GW Instek PSU Series Specifications

General IconGeneral
BrandGW Instek
ModelPSU Series
CategoryPower Supply
LanguageEnglish

Related product manuals