5-32 3. SHARP PLC
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
*1 File Register Setting on V-SFT Editor
Enter “file number” + “: (colon)” + address in order.
Memory TYPE Remarks
X9XXX (register) 0
XXXXX (relay) 1 ] for word device
EXXXX (self diagnosis) 2
bXXXX (timer counter) 3
Fn (file register) 7 *1
Example: F1 : 00002
Address
Colon
File number