EB+ Gen3 Installation guide
102 Innovative Vehicle Solutions 2013
The EB+ Gen3 system has two power up modes to aid in system testing. With switching the Ignition ‘On’
(B+ applied) the following occurs:
With no yellow line pneumatic pressure (i.e. brakes ‘Off’).
The system adopts load sensing mode when the brakes are applied. This load sensing mode is limited to 2
minutes for any single brake application, after which it returns to a push-through condition (approx 1:1).
The push-through condition is cancelled on vehicle movement above 10 km / h returning the system to load
sensing operation.
With yellow line pneumatic pressure (i.e. Brakes ‘On’, park on air).
Apply foot brake, switch Ignition ‘On’.
The system adopts a push-through (approx 1:1) condition. When the brakes are released and re-applied the
system remains in push-through unless the brakes are released for longer than 2 minutes, after which it returns to
load sensing operation.
This condition is cancelled on vehicle movement above 10 km / h returning the system to load sensing operation.