EB+ Gen3Installation guide
1152013 Innovative Vehicle Solutions
K
Layout the sensor cable route. Ensure sensor cable is
not under tension and not fouling brake shoe. Avoid
any sharp edges and moving parts. The cable exit from
the brake torque plate or dirt shield should be via a
grommet ‘K’.
Reassemble hub assembly
Sensor must be central over the exciter teeth.
The gap between exciter ‘M’ and sensor ‘l’ must not
exceed N = 0.5 mm.
Maximum run out of 0.2 mm true indicator reading.
Before fitment of hub cap / cover check sensor output.
N
IM