EasyManua.ls Logo

Haldex EB+ Gen3 - Example - AUX 1 Connection; ECU Connectors - Sensor; AUX; DIAG

Haldex EB+ Gen3
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EB+ Gen3 Installation guide
78 Innovative Vehicle Solutions 2013
Blanking
plugs
AUX 1
connection
ECU connectors – sensor & AUX
The ECU is supplied with blanking plugs in positions
indicated. These require to be removed to allow
fitment of additional sensors or permitted ancillary
equipment.
Example - AUX 1 connection
Identify the AUX 1 position on the front face of the
ECU.
Locate the locking tag ‘O’ position.
With a tool ‘P’ having a flat end of Ø3-2 mm insert
and press in locking tab of plug. While depressed pull
out plug from housing.
Identify orientation:
Sensor black body connector
Auxiliary blue body connector
Diagnostic black body connector
Ensure contact pins and seal are kept clean and free
of any contamination prior to installation. Insert fully
home.
ECU ECU
O
ECU
Ø 3.0
2.0
P
‘Click’