289
_____________________________________________________________________
15.1 Logic Inputs
______________________________________________________________
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
AP
P
IND
The number of channels 4 (insulated between product and channels)
Input voltage range LOW HIGH
Input resistance 30 kΩ min 100 kΩ min
Sensitivity (Output: L) 0to10VAC
(0 to 15) V DC
0to30VAC
(0 to 43) V DC
Sensitivity (Output: H) 60 to 150 V AC
(20 to 150) V DC
170 to 250 V AC
(70 to 250) V DC
Response time ( )
()
Less than 1 ms
Less than 3 ms
with 100 V DC
Less than 1 ms
Less than 3 ms
with 200 V DC
Maximum input voltage 150 V rms 250 V rms
Maximum rated voltage
to earth
250 V rms
Dielectric strength 2.3 kV AC /1 min
(between product and channels)
Insulation resistance More than 100 MΩ /500VDC
(between product and channels)
This product detects absolute
values so that negative DC
voltages can be applied. The
above values for AC voltages
are those obtained with sine
wave signals of 50/60 Hz.
NOTE
Refer to the manual supplied with the 9321-01 LOGIC PROBE
for details.
9321-01 LOGIC PROBE
Use to determine whether power to a circuit is on or off.
Set the input selector according to the measured voltage.
LOW range: 100 V AC or 24 V DC
HIGH range: 200 V AC
The inputs are bipolar, so polarity may be disregarded.
As the inputs are isolated, each channel can be connected
to points with different potential.