160
_____________________________________________________________________
8.8 Internal Trigger
______________________________________________________________
Flashing cursor
OFF
Logic trigger is not used.
OR
Triggering occurs if any one of the logic input signals
conforms to the trigger pattern.
AND
Triggering only occurs if all of the logic input signals
conforms to the trigger pattern.
8.8.6 Logic Trigger
The signal of a logic channel can be used as trigger source.
A trigger pattern and logical operator (AND/OR) are
specified, and triggering occurs when the trigger conditions
are met. A trigger filter can be specified, so that triggering
occurs only when the trigger conditions are met within the
filter width.
Procedure
Trigger Screen
1. Press the
SET
button to display the Trigger Screen.
2. Move the flashing cursor to the position shown in the
figure below and use the
buttons to make a setting.