Appendix 1 Error Messages and Remedial Actions
A2
When there is a warning, a warning message will appear just once and then disap-
pear after a few seconds. A displayed warning message can be closed by pressing
any key.
015
The possible zero-adjustment range
has been exceeded.
INSTNT error: ....
RMS error: ....
There is a problem with the input section. If the er-
ror message appears after turning the power off
and then back on, the instrument needs to be re
-
paired.
030
The printer has been stopped be-
cause a head temperature error was
detected.
Wait until the temperature of the printer falls be-
fore using the printer
031
The printer has been stopped be-
cause a motor temperature error was
detected.
Wait until the temperature of the printer falls be-
fore using the printer
032
The printer was stopped for an error
of the motor.
There is a problem with the printer motor. If the er-
ror message appears after turning the power off
and then back on, the printer needs to be re
-
paired.
Message Remedial Action
Warning Messages
Message Remedial Action
101
Invalid key.
Keys are disabled while measuring. Try operating
again when measurement is finished.
102
Cannot start measurement.
The START and STOP keys are disabled when the
current screen is displayed.
103
Cannot change while measuring.
Press STOP to stop measuring before changing the
setting.
104
Voltage drop and wave compari-
son triggers cannot be modified.
(The effective time axis range is
100
μs/div to 20ms/div and the ef-
fective recording interval is 1μs to
200μs.)
Set the time base range or recording interval to a val-
id range.
105
Voltage drop and wave compari-
son triggers have already been
set and cannot be modified.
(The effective time axis range is
100
μs/div to 20ms/div and the ef-
fective recording interval is 1μs to
200
μs.)
Disable the voltage drop and waveform judgment
triggers.
106
This cannot be used in RMS mode
(voltage drop and wave compari-
son trigger).
Change the measurement mode of the correspond-
ing channels to instantaneous value.
201
Exceeding the setting range.
The entered numerical value exceeds the setting
range. Enter an appropriate value.

Table of Contents

Other manuals for Hioki MEMORY HiCORDER MR8880