-113-
MAINTENCE AND ADJUSTMENT OF THE UTV
- 113 -
different from those of conventional batteries.
The MF battery should be charged as explained
in the charging method illustrations. If the
battery is overcharged, the electrolyte level
will drop considerably;
• Therefore, take special care when charging
the battery.
NOTE:
Since MF batteries are sealed, it is not possible
to check the charge state of the battery by
measuring the specific gravity of the electrolyte.
Therefore, the charge of the battery has to be
checked by measuring the voltage at the battery
terminals.
1. Remove:
Lift the hood up;
battery case cover;
disconnect;
battery leads
NOTE:
First, disconnect the negative battery lead ,
and then the positive battery lead .
Remove;
battery
Check;
battery charge
a.
Connect a pocket tester to the battery terminals.
Positive tester probe
positive battery terminal
Negative tester probe
negative battery terminal

Table of Contents