Set the following items on Web console.
- IP address for LPAR manager
- Subnetmask
- VNIC System No.
- Time zone
For details about logical partitioning, LPAR manager firmware
selection, and LPAR manager initial settings, see the Hitachi Compute
Blade 500 Series Server Blade Setup Guide.
•
The operating conditions are satisfied for the OS and application.
• When setting the N+M cold standby using Emulex 8 Gb 2-port Fibre
Channel mezzanine card or Emulex 16 Gb 2-port Fibre Channel mezzanine
card, all setup menu items of HBA BIOS configuration transfer to the
server blade configuration.
¢
Fibre Channel switch cascade number
¢
The port speed setting of Fibre Channel switch
¢
The port speed/topology setting of disk drive
• When setting the N+M cold standby using Emulex 10Gb CNA/LAN
mezzanine card, the following settings must be required for configuration
of Emulex 10Gb CNA/LAN mezzanine card and onboard 2-port or 4-port
CNA in the active server blade and the standby server blade.
¢
The active server blade and the standby server blade have the same
MultiChannel Support configuration.
¢
The active server blade and the standby server blade have the same
Personality configuration.
¢
For CNA/LAN mezzanine card and onboard CNA (2 ports), specify NIC
or iSCSI as the Personality setting. For onboard CNA (4 ports), specify
NIC or NIC+RoCE as the Personality setting.
¢
DHCP in iSCSI setting is disabled.
¢
iSCSI Initiator has a unique IP address.
¢
iSCSI Target is always connected.
¢
The number of iSCSI Target sessions is up to four per port.
For details of the MultiChannel Support configuration and Personality
configuration, see the OneCommandManager Guide.
Note:
•
Switching server blades with the N+M cold standby do not operate
properly if Emulex 10 Gb CNA/LAN mezzanine card or onboard CNA,
which is installed in the active server blade and standby server blade,
does not have the above configuration.
• Use the firmware versions below to inherit the following settings in N+M
cold standby:
- The NIC setting of the Emulex 10 Gb CNA/LAN expansion cards for the
CB 520H A1/B1 and CB 520A A1 models
- The NIC setting of the onboard CNA (2 ports)
Functional detail
2-77
Hitachi Compute Blade 500 Series Management Module Setup Guide