Table 2-110 CLI console operation
Item Operation
Displaying the chassis power history show log power
Setting forced power off order for server blades
The management module forces power off the server blades to maintain the
power for remaining server blades when the power consumption exceeds the
available supply power because of the failure of power supply modules. You
can set the forced power off order from the management module Web
console.
The default order is sever blade #7, #6, #5, #4, #3, #2, #1 and #0.
Table 2-111 Web console operation
Item Operation
Displaying/setting forced power off
order
Resources tab > Systems > Power
management
Power supply module optimization
Power supply module optimization statically optimizes the number of power
supply modules to activate according to that of server blades to be operated
so that the power supply modules can work efficiently. This function is
enabled in default. The LEDs of inactive power supply modules blink in green
while the function is enabled.
Table 2-112 Web console operation
Item Operation
Displaying power supply
module optimization
Resources tab > Systems > Power management
Setting power supply module
optimization
Resources tab > Systems > Power management
>
Action button > Edit power supply module
optimization
Table 2-113 CLI console command
Item Command
Displaying the function status show power ps-module
Enabling/disabling the function Set power ps-module
Functional detail
2-227