Table 2-11 Web console operation
Item Operation
Initializing PIN Administration tab > Users and Roles > Action
button >
Initialize LCD PIN
Table 2-12 LCD touch console operation
Item Description
PIN settings System settings
> PIN
• Disabling validity
The LCD touch console function can be disabled on the system unit. When
it is disabled, you cannot operate the LCD touch console even if
connecting it to the system unit.
The factory default is Enabled. You can change values from CLI console.
Table 2-13 CLI touch console operation
Item Description
Showing LCD touch console setting for validity show lcd setting
Setting LCD touch console validity set lcd validity
Time settings
This section describes time setting methods for management modules.
Time settings for management module
You can set up the date, time, the time zone, and the daylight saving time in
the management module. Set correct settings in the management module
before starting operation.
Table 2-14 Web console operation
Item Operation
Displaying/setting time information Administration tab > Date and time
Table 2-15 CLI console command
Item Command
Displaying time information
show time local
show time timezone
2-8
Functional detail
Hitachi Compute Blade 500 Series Management Module Setup Guide