Figure 2-7 System unit configurations for LFT
The LFT targeted port is MGMT0 and MGMT1. These ports can be set enabled/
disabled independently, and the each factory default setting is enabled.
MGMT0 and MGMT1 are switched separately, so only one port that is
connected to a failed switch is switched when different switches are
connected to MGMT0 and MGMT1 separately.
When link down on a port in the active management module is detected for
continuous three second during the LFT is enabled, the port is disconnected.
After the port switching, when link up on the failed port in the management
module is detected for continuous 180 seconds, the port is switched.
The link down detection time for failover and link up detection time for
recovery are selectable between one and 3600 seconds.
Table 2-32 Web console operation
Item Operation
Displaying/setting LFT function Resources tab > Systems > Network
> Link Fault
Tolerance
Security
This section describes security features provided by management interfaces
of the management module and BMC.
2-26
Functional detail
Hitachi Compute Blade 500 Series Management Module Setup Guide