• "Restart BMC" is used for recovery when an error occurs. Do not use it in
usual operation.
Tip: "Power OFF" is an emulation of pressing the server blade power button
for a second. "Force power OFF" is also that of pressing the server blade
power button for four seconds.
Table 2-50 Web console operation
Item Operation
Power on, Power off, Forced
power off, Hard reset, Issuing
NMI
Resources
tab > Modules > All Modules > Server
Blades > Server Blade x > Condition tab
Rebooting BMC Resources tab > Modules > All Modules > Server
Blades > Server Blade x > BMC tab
Note:
*x: One of Server blade 0 – 7
Table 2-51 CLI console command
Item Command
Turning on
poweron blade
Turning off / Forced turning off
poweroff blade
Hard reset / Issuing NMI
reset blade
Rebooting BMC
bmc-reset blade
Operating power supply for switch module
You can turn on or off the switch module by the management module.
Tip: The switch module boot up automatically when turn on AC. You do not
need turn the switch module on.
Table 2-52 Web console operation
Item Operation
Operating power supply for switch
module
Resources tab > Modules > All modules >
Switch Module > Switch Module x
Note:
*x: One of Switch module 0 – 3
Server blade operation setting when power failure recovery
You can perform the server blade operations as following by setting the
management module configuration when turning on the system unit.
Functional detail
2-43
Hitachi Compute Blade 500 Series Management Module Setup Guide