Figure 1-1 Port location of management module
Table 1-1 Port type of management module
Port name Specification
Management LAN
port (MGMT0)
This port is connected to the management LAN.
For the factory default setting, this port is connected to the
management LAN.
Management LAN
port (MGMT1)
This port is connected to the management LAN.
For the factory default setting, this port cannot be connected to
the management LAN.
For details, see Network on page 2-11.
Maintenance LAN
port (MAINT)
This port is dedicated for customer engineers for maintenance
purposes.
The user can not use this port.
Serial port (SER) This serial port is for the system console.
Use this port for the initial setting. You can also use this port
when the LAN port cannot be used or the system unit is
performed initial setting.
Tip: You need to prepare following items for LAN port connection.
•
System console
• UTP cable (UTP-5 or higher)
• Client software for HTTP, Telnet, or SSH
The following table describes specification of the factory default network
settings for management module, which are required to connect to HTTP,
Telnet, or SSH.
Table 1-2 Network settings for management module (factory default
settings)
Item Specification
IP address 192.168.0.1
Management module overview
1-3
Hitachi Compute Blade 500 Series Management Module Setup Guide