The following table shows the specification of SNMP polling.
Table 2-119 Specification of SNMP polling
Item Specification
Supporting instruction SNMPv1/v2c/v3 (Get, GetNext, GetBulk)
Maximum number of simultaneous
notify SNMP manager
8
Supporting module Sever blade, Management module, Switch module,
Power supply module, Fan module
The following table shows the specification of SNMP trap.
Table 2-120 Specification of SNMP trap
Item Specification
Notification method SNMP (SNMPv2Trap/
SNMPv3Trap )
Maximum number of simultaneous notify SNMP
manager
8
Notification trigger Recording failure SEL in the
management module
Notification content First variable binding Time of failure
Second variable binding Chassis of failure
Third variable binding Failure level
Fourth variable binding SVP alert ID for the trap
Fifth variable binding Failure message
Sixth variable binding Failure portion
2-234
Functional detail
Hitachi Compute Blade 500 Series Management Module Setup Guide