Module Default setting Note
Server blade Connection from
MGMT0
-
Switch module Connection from
MGMT0
Except Brocade 10 Gb/sec DCB switch
module, switch modules cannot connect
from MGMT0 since the management
interface is assigned to the internal
network.
Table 2-23 Web console operation
Item Operation
Connection procedure,
displaying VLAN
Resources
tab > Systems > Network > Management
LAN > VLAN tab
Table 2-24 CLI console command
Item Command
Connection procedure,
Displaying VLAN
show network vlan
Connection procedure,
Setting VLAN
set network vlan
Deleting VLAN
delete network vlan
Connecting management interface from MGMT1
The system unit has connection ports, MGMT0 and MGMT1, for the
management interface. You can select which connection port is assigned for
each module. For examples, you can set the following configurations.
•
The management module connects to MGMT0, and the server blades and
switch modules connect to MGMT1. The network is separated clearly
according to the managed entities.
• The server blades #0-3 connect to MGMT0, and the server blades #4-7
connect to MGMT1 for load balancing.
2-16