HP 1660 Series - Define a Term for the State Trigger

HP 1660 Series
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Define a Term for the State Trigger
For the state analyzer to capture the data you want, you need to tell it what
to trigger on by defining a term. Trigger terms are used in the trigger
specification to tell the analyzer when to start recording data, what to store,
and when to stop.
1
Press the Trigger MENU key.
2 Highlight the base field under SCOUNT, and press the Select key.
Highlight
Hex in the pop-up menu, and press the Select key.
Hex is the default setting. Notice that there are other display options other
than hex.
3
Under SCOUNT, highlight the field to the right of b, enter 00, and
press the
Done key.
The "b" term is a variable to which you can assign a value.
Define a Term for the State Trigger
Result SCOUNT’s "b" term is assigned the value 00 (hex). The "b" term is a variable
that the analyzer will trigger on once you set up the trigger specification in
the next exercise.
The base field is used
to specify the type of
values entered.
A term is a variable that
stores a value. In this
exercise, you selected
Hex, and entered the
hex value 00 for the "b"
term.
Introduction to State Analysis