Turn On the Timing Analyzer
Now you will begin to set up the timing analyzer to capture the glitch.
1 Highlight the Scope field and press the Select key. Highlight Analyzer in
the pop-up menu, and press the
Select key.
2 Press the Config MENU key.
If the Configuration menu is already displayed when you press the Config key,
then a pop-up menu will appear. Choose Configuration from the pop-up menu.
3
Highlight the field to the right of Type in the Analyzer 1 box and
press the
Select key. Highlight Timing in the pop-up menu, and press
the
Select key.
Result Analyzer 1 is set to timing mode.
Triggering the Oscilloscope with the Timing Analyzer
Turn On the Timing Analyzer
8-8