EasyManuals Logo

HP 5920 Series User Manual

HP 5920 Series
607 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #113 background imageLoading...
Page #113 background image
100
Field Descri
p
tion
Calculation trigger type
Route calculation trigger type:
• Full—Calculation of all routes is triggered.
• Area topology change—Topology change in an area.
• Intra router change—Incremental intra-area route change.
• ASBR change—Incremental ASBR route change.
• 7to5 translator—Type-7-to-Type-5 LSA translator role
change.
• Full IP prefix—Calculation of all IP prefixes is triggered.
• Full intra AS—Calculation of all intra-AS prefixes is
triggered.
• Inc intra AS—Calculation of incremental intra-AS prefixes is
triggered.
• Full inter AS—Calculation of all AS-external prefixes is
triggered.
• Inc inter AS—Calculation of incremental AS-external
prefixes is triggered.
• N/A—Route calculation is not triggered.
Current calculation type
Current route calculation type:
• SPF calculation.
• Intra router calculation—Intra-area route calculation.
• ASBR calculation—Inter-area ASBR route calculation.
• Inc intra router—Incremental intra-area route calculation.
• Inc ASBR calculation—Incremental inter-area ASBR route
calculation.
• 7to5 translator—Type-7-to-Type-5 LSA calculation.
• Full intra AS—Calculation of all intra-AS prefixes.
• Inc intra AS—Calculation of incremental intra-AS prefixes.
• Full inter AS—Calculation of all AS-external prefixes.
• Inc inter AS—Calculation of incremental AS-external
prefixes.
• Forward address—Forwarding address calculation.
• N/A—Route calculation is not triggered.
Current calculation phase
Current route calculation phase:
• Calculation area topology—Calculating area topology.
• Calculation router—Calculating routes on routers.
• Calculation intra AS—Calculating intra-AS routes.
• 7to5 translator—Calculating Type-7-to-Type-5 LSAs.
• Forward address—Calculating forwarding addresses.
• Calculation inter AS—Calculating AS-external routes.
• Calculation end—Ending phase of calculation.
• N/A—Route calculation is not triggered.
Process reset state
Process reset state:
• N/A—The process is not reset.
• Under reset—The process is in the reset progress.
• Under RIB smooth—The process is synchronizing the RIB.

Table of Contents

Other manuals for HP 5920 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5920 Series and is the answer not in the manual?

HP 5920 Series Specifications

General IconGeneral
BrandHP
Model5920 Series
CategorySwitch
LanguageEnglish

Related product manuals