4-22 Chapter 4
D200/D210/D310 Front Panel LCD Codes
Table 4-14 Boot Device Initialization and IPL codes for all other paths.
Table 4-15 TOC codes.
Ostat Code Name Meaning
INIT C700 GET_MANUF_DFLTS Retrieving Manufacturing defaults.
INIT C740 INIT_MANUF_DFLTS
INIT C740 INIT_OTHR_PATH Initializing manufacturing defaults.
TEST C750 TEST_OTHR_PATH Initializing a non-primary boot path.
INIT C780 LOAD_IPL_OTHR_PATH Loading IPL from a non-primary boot
device.
WARN C7F0 OTHR_IPL_FAULT Error occurred reading IPL from boot
media.
WARN C7F1 BAD_IPL_ADDR_OTHR LIF file address is not 2K byte aligned or it
is zero.
WARN C7F2 BAD_LIF_MAGIC_OTHR LIF file not present on media.
WARN C7F3 BAD_IPL_SIZE_OTHR LIF file is not a multiple of 2K bytes, is zero
or it is greater than 256K bytes.
WARN C7F4 BAD_IPL_ENTRY_OTHR LIF file entry is not word aligned or is
greater than or equal to the size.
WARN C7F8 BAD_IPL_CHECKSUM_OTH
R
The arithmetic sum of the words in IPL 0.
INIT C7FF LAUNCH_IPL_OTHR Branching to IPL form a non-primary boot
device.
Ostat Code Name Meaning
INIT CB00 TOC_INITIATED TOC handler entered
TEST CB0B BR_TO_OS_TOC Branching to OS_TOC