Chapter 5 5-27
Dx50/Dx60 Front Panel LCD Codes
INIT CBF8 PDC_IO initialization completed
WARN CBF9 PDCE_HPMC or PDC_IO found unconfigured IOA or bus converter
WARN CBFA Previous HPMC PIM logged, current HPMC can not be logged
FLT CBFB Branching to the OS HPMC handler
FLT CBFC Branch to OS HPMC failed
FLT CBFE HPMC interrupted a TOC
FLT CBFF Nested HPMC occurred
INIT CC0x Operating System rendezvous, Where x = CPU
INIT CC1x Early CPU rendezvous, Where x = CPU
INIT CC2x CPU rendezvous, Where x = CPU
INIT CC3x Cache CPU rendezvous, Where x = CPU
INIT CC4x Memory CPU rendezvous, Where x = CPU
FLT CCF0 CPU slave fault
TEST CD00 I/O Adapter test
INIT CDxy Indicates system found a device and is resetting it; x = bus and y = slot
FLT CDxy Indicates system found a device error; x = bus and y = slot
INIT CD04 Initialize I/O Adapter 0
INIT CD05 Initialize I/O Adapter 1
INIT CDxC Initialize Graphics; x = HSC bus number
INIT CDxD (init hyperdrive) x = GSC+ bus number (graphics hyperdrive/dodger)
INIT CDxF (init lasi) x = GSC+ bus number
INIT CDFF Building the system map table
Ostat Code Description