6-24 Chapter 6
D270/D370, D280/D380/R380 and D390/R390 Front Panel LCD Codes
FLT CBF1 OS did not replace PDC IVA
FLT CBF2 Invalid length for OS HPMC code
FLT CBF3 Invalid address for OS HPMC code
FLT CBF4 Invalid checksum for OS HPMC code
FLT CBF5 IVA + 32 was equal to zero
INIT CBF7 PDC_IO initialization started
INIT CBF8 PDC_IO initialization completed
WARN CBF9 PDCE_HPMC or PDC_IO found unconfigured IOA or bus converter
WARN CBFA Previous HPMC PIM logged, current HPMC can not be logged
FLT CBFB Branching to the OS HPMC handler
FLT CBFC Branch to OS HPMC failed
FLT CBFD Check for no known reason
FLT CBFE HPMC interrupted a TOC
FLT CBFF Nested HPMC occurred
INIT CC0x Operating System rendezvous, Where x = CPU
INIT CC1x Early CPU rendezvous, Where x = CPU
INIT CC2x CPU rendezvous, Where x = CPU
INIT CC3x Cache CPU rendezvous, Where x = CPU
INIT CC4x Memory CPU rendezvous, Where x = CPU
FLT CCF0 CPU slave fault
TEST CD00 I/O Adapter test
INIT CDxy Indicates system found a device and is resetting it; x = bus and y = slot
FLT CDxy Indicates system found a device error; x = bus and y = slot
INIT CD04 Initialize I/O Adapter 0
INIT CD05 Initialize I/O Adapter 1
INIT CDxC Initialize Graphics; x = HSC bus number
INIT CDxD (init hyperdrive) x = GSC+ bus number (graphics hyperdrive/dodger)
INIT CDxF (init lasi) x = GSC+ bus number
INIT CDE0 Initialization of EISA complete
INIT CDEA Initialize EISA
Ostat Code Description