Information Commands 23
SNMPv3 dump
The following command displays SNMPv3 information:
show snmp-server v3
Command mode: All
Engine ID = 80:00:07:50:03:00:0F:6A:F8:EF:00
usmUser Table:
User Name Protocol
-------------------------------- --------------------------------
admin NO AUTH, NO PRIVACY
adminmd5 HMAC_MD5, DES PRIVACY
adminsha HMAC_SHA, DES PRIVACY
v1v2only NO AUTH, NO PRIVACY
vacmAccess Table:
Group Name Prefix Model Level Match ReadV WriteV NotifyV
---------- ------ ------- ------------ ------ ------- -------- ------
admin usm noAuthNoPriv exact org org org
v1v2grp snmpv1 noAuthNoPriv exact org org v1v2only
admingrp usm authPriv exact org org org
vacmViewTreeFamily Table:
View Name Subtree Mask Type
-------------------- --------------- ------------ --------------
org 1.3 included
v1v2only 1.3 included
v1v2only 1.3.6.1.6.3.15 excluded
v1v2only 1.3.6.1.6.3.16 excluded
v1v2only 1.3.6.1.6.3.18 excluded
vacmSecurityToGroup Table:
Sec Model User Name Group Name
---------- ------------------------------- -----------------------
snmpv1 v1v2only v1v2grp
usm admin admin
usm adminsha admingrp
snmpCommunity Table:
Index Name User Name Tag
---------- ---------- -------------------- ----------
snmpNotify Table:
Name Tag
-------------------- --------------------
snmpTargetAddr Table:
Name Transport Addr Port Taglist Params
---------- --------------- ---- ---------- ---------------
snmpTargetParams Table:
Name MP Model User Name Sec Model Sec Level
-------------------- -------- ------------------ --------- -------