6. To decode the blinking state of server LED, review the entire SEL and look at events with alert
level 2 and above.
For example:
Log Entry 24: 14 Feb 2003 15:27:02
Alert Level 3: Warning
Keyword: Type-02 1b0800 1771520
Hot Swap Cage: SCSI cable removed
Logged by: BMC; Sensor: Cable / Interconnect - SCSI ChExt Cable
Data1: Device Removed/Device Absent
0x203E4D0AC6020220 FFFF0008F61B0300
Log Entry 73: 00:00:12
Alert Level 3: Warning
Keyword: Type-02 050301 328449
The server's built-in sensors have detected an open chassis door.
Logged by: BMC; Sensor: Physical Security - Chassis Open
Data1: State Asserted
0x200000000C020570 FFFF010302050300
Supported Configurations
This subsection provides examples of how to use the iLO 2 MP to acquire configuration information
for troubleshooting purposes. It also provides a system build-up procedure.
For a list of all FRUs in the server blade, with their corresponding part numbers, see Appendix A
(page 146).
System Build-Up Troubleshooting Procedure
Use this procedure only when the server powers on and remains powered on but does not enter
into or pass POST, or does not boot to EFI menu.
1. Remove the access panel to gain access to internal FRUs. See “Removing the Server Blade
Access Panel” (page 112).
2. Remove all of the HDDs from the front of the chassis. See “Removing a SAS Disk Drive
(page 108).
3. Remove the memory DIMMs. See “Removing a DIMM” (page 114).
4. Remove the processors. See “Removing a Processor (page 116).
5. Replace the server blade in the enclosure. The server blade (and MP) powers on.
6. Enter the DF command from the MP Console Menu. The following displays:
CM> DF
Display FRU Information Menu:
S - Specific FRU
A - All available FRUs
V - Display Mode: Text
7. Enter S to show the FRU IDs. The following displays:
FRU IDs:
--------
0001-Comm Module 0002-Disk Backplane
0003-Mezzanine Board 0000-Motherboard
If you do not see all of the above FRU IDs, then concentrate on the missing FRU ID(s). The
following alert (IPMI) event displays for this action, as read from the SEL:
Log Entry 4: Dec 2005 00:00:09
Alert Level 7: Fatal
Keyword: Type-02 257100 2453760
Missing FRU device - DIMM0A
Logged by: Baseboard Management Controller,
Supported Configurations 101

Table of Contents

Other manuals for HP Integrity BL860c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity BL860c and is the answer not in the manual?

HP Integrity BL860c Specifications

General IconGeneral
BrandHP
ModelIntegrity BL860c
CategoryServer
LanguageEnglish

Related product manuals