286 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
Action: Perform the following steps to resolve the problem. Stop when the
problem is resolved.
2.
1. Press the server blade management module reset button.
Replace the power backplane.
For more information, refer to the HP BladeSystem Maintenance and Service
Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-
class/info).
Server blade management module power backplane B error codes
LED Code: 12-1, 12-2, 12-3, or 12-4
Location: Server blade power backplane B
Action: Perform the following steps to resolve the problem. Stop when the
problem is resolved.
1. Press the server blade management module reset button.
2. Replace the power backplane.
For more information, refer to the HP BladeSystem Maintenance and Service
Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-
class/info).
Interconnect A Error Code
LED Code: 13-1, 13-2, 13-3, or 13-4
Location: Interconnect Device - Side A
Action: Perform the following steps to resolve the problem. Stop when the
problem is resolved.
1. Press the server blade management module reset button.
2. Reseat the interconnect device.
For more information, refer to the HP BladeSystem Maintenance and Service
Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-
class/info).