288 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
3. Replace the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service
Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-
class/info).
Interconnect Module B (10-Connector) Error Code
LED Code: 16-1 or 16-2
Location: Side B Interconnect Module (10-connector)
Action: Perform the following steps to resolve the problem. Stop when the
problem is resolved.
1. Press the server blade management module reset button.
2. Reseat the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service
Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-
class/info).
3. Replace the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service
Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-
class/info).
Interconnect Module A (6-Connector) Error Code
LED Code: 17-1 or 17-2
Location: Side A Interconnect Module (6-connector)
Action: Perform the following steps to resolve the problem. Stop when the
problem is resolved.
1. Press the server blade management module reset button.
2. Reseat the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service
Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-
class/info).