Troubleshooting 289
3. Replace the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service
Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-
class/info).
Interconnect Module B (6-Connector) Error Code
LED Code: 18-1 or 18-2
Location: Side B Interconnect Module (6-connector)
Action: Perform the following steps to resolve the problem. Stop when the
problem is resolved.
1. Press the server blade management module reset button.
2.
For more information, refer to the HP BladeSystem Maintenance and Service
Guide on the HP website (
Reseat the interconnect module.
http://www.hp.com/products/servers/proliant-bl/p-
class/info).
3. Replace the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service
Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-
class/info).
Unknown server blade management module error code
LED Code: 19-1
Location: Unknown
Action: Perform the following steps to resolve the problem. Stop when the
problem is resolved.
1. Press the server blade management module reset button.
2. Replace the server blade management module.