EasyManua.ls Logo

HP StorageWorks P9000 - Ykdemo09

HP StorageWorks P9000
399 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
/*
* Close the EMCS console interface that was opened by the previous
* YKCONMSG OP(OPEN) call. Note that the return code for YKCONMSG with
* the OP(CLOSE) parameter is 6 if it completed successfully.
*/
address TSO "YKCONMSG OP(CLOSE) HANDLE(x'"HandlerValue"')"
/*
* Check the return code to see if it is 6 or not. Note that the return
* code for YKCONMSG with the OP(CLOSE) parameter is 6 for
* successful completion.
*/
if rc /= 6
then do
say "YKCONMSG OP(CLOSE) failed."
exit
end
else
nop
say "#-- END YKDEMO08."
exit
/*
* printErrorMessage: This procedure prints all of the error messages
* in the Message structure when a CLI command failed.
*/
printErrorMessage: procedure expose DEMO_MSG.
do x = 1 to DEMO_MSG.0
say "Severity = " || DEMO_MSG.x.Severity
say "Text = " || DEMO_MSG.x.Text
say "Value = " || DEMO_MSG.x.Value
end
return 0
YKDEMO09
/* REXX */
/**********************************************************************/
/* */
/* All Rights Reserved. Copyright (C) 2009, 2010, Hitachi, Ltd. */
/* */
/**********************************************************************/
/* */
/* YKDEMO09 - A sample demonstration script that illustrates */
/* how to use the Business Continuity Manager's CLI commands to */
/* perform fail-back operations in a 2DC configuration with */
/* HyperSwap and UR. */
/* This script can be used when DKC at the primary site has been */
/* stopped for a DKC maintenance or because a DKC failure has */
/* occurred. */
/* */
/* This sample script assumes the following settings: */
/* */
/* 1) The definition files are stored in the dataset with the */
/* prefix "BCM.DEMO". */
/* 2) The TC copy group's copy group ID is MYTCHS. */
/* 3) The copy group ID between the primary and */
/* remote sites is MYUR1. */
/* 4) The copy group ID between the local and */
/* remote sites is MYUR2. */
/* 5) The route list ID is "DEMORLST". */
/* 6) The primary Device Address Domain ID is "PRIM". */
/* */
Command details 293

Table of Contents

Other manuals for HP StorageWorks P9000