Loading...
NOTE: You can use the YKDROP command to drop the REXX variables in any copy group structure
that was loaded by using the YKLOAD command.
Table 146 (page 324) shows the copy group structure when a configuration file is loaded. The
prefix for the name of the copy group structure is stem-name-specified-in-STEM-parameter. Each
REXX variable is preceded by a period ('.').
Table 146 Copy Group Structure
DescriptionREXX variables
Last update IDUpdateID
Copy group IDID
SIMPLEX count (sum value of
CopyGroup.n.SimplexCt)
SimplexCt
PENDING count (sum value of
CopyGroup.n.PendingCt)
PendingCt
DUPLEX count (sum value of
CopyGroup.n.DuplexCt)
DuplexCt
TRANS count (sum value of
CopyGroup.n.TransitionCt)
TransitionCt
SUSPOP count (sum value of
CopyGroup.n.SuspendOpCt)
SuspendOpCt
SUSPCU count (sum value of
CopyGroup.n.SuspendCuCt)
SuspendCuCt
SUSPVS count (sum value of
CopyGroup.n.SuspendVSCt)
SuspendVSCt
SWAPPING count (sum value of
CopyGroup.n.SwappingCt)
SwappingCt
1
Count of copy pairs with reverse direction
from Secondary to Primary (sum value of
CopyGroup.n.ReversedCt)
ReversedCt
SUSPER count (sum value of
CopyGroup.n.SuspendErCt)
SuspendErCt
INVALID count (sum value of
CopyGroup.n.InvalidCt)
InvalidCt
REVRSY count (sum value of
CopyGroup.n.RevrsyncCt)
RevrsyncCt
HOLD count (sum value of
CopyGroup.n.HoldCt)
HoldCt
HOLDER count (sum value of
CopyGroup.n.HoldErCt)
HoldErCt
CHKJNL count (sum value of
CopyGroup.n.ChkJnlCt)
ChkJnlCt
20
HOLDTRNS count (sum value of
CopyGroup.n.HoldTrnsCt)
HoldTrnsCt
NODELTA count (sum value of
CopyGroup.n.NoDeltaCt)
NoDeltaCt
CONSLOST count (sum value of
CopyGroup.n.ConslostCt)
ConslostCt
324 Data Objects