Specifications
Environmental specifications
Specification Value
Temperature range
1
—
Operating 10°C to 35°C (50°F to 95°F)
Nonoperating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)
—
Operating
Minimum to be the higher (more moisture) of -12°C
(104°F) dew point or 8% relative humidity
Maximum to be 24°C (752°F) dew point or 90% relative
humidity
Nonoperating
5% to 95%
387°C (1017°F), maximum wet bulb temperature
1
All temperature ratings shown are for sea level. An altitude derating of
10°C per 3048 m (18°F per 1000 ft) to 3048 m (10000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change
might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
• 5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 10°C per every
175 m (18°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m (10000 ft).
• 40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 10°C per every 125 m (18°F per every 410
ft) above 900 m (2953 ft) to a maximum of 3048 m (10000 ft).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise website.
Mechanical specifications
Specification
Value
Height 8750 mm (344 in)
Depth, SFF 71120 mm (2800 in)
Depth, LFF 74930 mm (2950 in)
Width 44540 mm (1754 in)
Weight, SFF minimum 1510 kg (3328 lb)
Weight, SFF maximum 1970 kg (4343 lb)
Weight, LFF minimum 1730 kg (3814 lb)
Weight, LFF maximum 2470 kg (5445 lb)
160 Specifications