9. Install the access panel.
10. Slide the server into the rack.
11. Connect each power cord to the server.
12. Connect each power cord to the power source.
13. Power up the server.
Installing the Systems Insight Display
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
The components included with the hardware option kit
T-10 Torx screwdriver
Procedure
1.
Power down the server.
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
4.
Remove the access panel.
5.
Do one of the following:
Remove the air bale.
If installed, remove the 4LFF midplane drive cage.
6.
Remove the fan cage.
7. Disconnect the power switch module cable from the power switch/SID module connector.
The SID module cable will be connected to this same connector.
8. Remove the power switch module. Retain the T-10 screw for later use.