For more information, see the documentation that ships with the rack mounting option.
4. Place the server on a sturdy, level surface.
Remove the access panel
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives, power supplies, and internal
system components to cool before touching them.
CAUTION: Do not operate the chassis for long periods with the access panel open or removed. Operating the
chassis in this manner results in improper airflow and improper cooling that can lead to thermal damage.
Procedure
1. Power down the server.
2. Extend the server from the rack.
3. Open or unlock the locking latch, slide the access panel to the rear of the chassis, and remove the access panel.
Install the access panel
Procedure
1.
Place the access panel on top of the server with the latch open.
Allow the panel to extend past the rear of the server approximately 125 cm (05 in).
2.
Push down on the latch.
The access panel slides to a closed position.
3.
Tighten the security screw on the latch, if needed.
Removing the fan cage
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server
in this manner results in improper airflow and improper cooling that can lead to thermal damage.
IMPORTANT: For optimum cooling, install fans in all primary fan locations.
Procedure
1. Power down the server.
2. Do one of the following:
• Disconnect each power cord from the power source.
• Disconnect each power cord from the server.
3. Do one of the following:
Operations
37