<Function 065> GS ( k pL pH cn fn n (cn = 48, fn = 65)
PDF417: Set the number of columns in the data region.
(pL + pH × 256) = 3 (pL = 3, pH = 0)
cn = 48
fn = 65
0 ≤ n ≤ 30
Set the number of columns in the PDF417 data region.
• When n=0, specifies automatic processing.
• When n is not 0, sets the number of columns in the data region to n
codeword.
The following data is not included in the number of columns:
• Start pattern and stop pattern
• Indicator codeword of left and right
<Function 066> GS ( k pL pH cn fn n (cn = 48, fn = 66)
PDF417: Set the number of rows.
(pL + pH × 256) = 3 (pL = 3, pH = 0)
cn = 48
fn = 66
n=0, 3 ≤ n ≤ 90
Sets the number of rows for PDF417.
• When n=0, specifies automatic processing, the number of rows is calculated
by the number of print data or print area.
• When n is not 0, sets the number of rows to n rows.