04/SHOCK ABSORBER, SWINGARM 48
200267-10
– As soon as the vacuum gauge has attained the specified value, turn the Oil reser-
voir control lever to Equalize pressure.
Guideline
4 mbar
The pressure gauge rises to the specified value.
0 bar
200268-10
– As soon as the pressure gauge has attained the specified value, turn the Damper
control lever to Pressure.
Guideline
0 bar
Oil is pumped into the shock absorber.
The pressure gauge rises to the specified value.
3 bar
200269-10
– As soon as the pressure gauge has attained the specified value, turn the Damper
control lever to Vacuum.
Guideline
3 bar
The pressure gauge drops to the specified value.
0 bar
200270-10
– As soon as the pressure gauge has attained the specified value, turn the Oil reser-
voir control lever to Vacuum.
Guideline
0 bar
The vacuum gauge drops to the specified value.
8 mbar
200267-10
– As soon as the vacuum gauge has attained the specified value, turn the Oil reser-
voir control lever to Equalize Pressure.
Guideline
8 mbar
The pressure gauge drops to the specified value.
0 bar
200268-10
– As soon as the pressure gauge has attained the specified value, turn the Damper
control lever to Pressure.
Guideline
0 bar
Oil is pumped into the shock absorber.
The pressure gauge rises to the specified value.
3 bar