Table A-1 (Page 7 of 9). Service Request Numbers
SRN FRU List % Problem
60000 SSA adapter card 100 Description: The SSA adapter is missing
from the expected configuration.
Action: Verify that the SSA adapter card
is installed in the expected slot of the
using-system.
If it is in the expected slot, exchange
the FRU for a new FRU.
If it is not in the expected slot, enter
the diag -a command, and answer the
questions that are displayed.
60240 None 100 Description: A configuration problem has
occured.
Action: A device cannot be configured,
for some unknown reason. Go to “MAP
2010: SSA Hot-Swap Disk Drive–Start” on
page 2-37. If no problem is found go
to“Software and Microcode Errors” on
page A-5.
7
xxxx
Disk drive module
Backplane assembly
80
20
Description: An SSA Hot-Swap Disk
Drive module is missing from the expected
configuration of the SSA loop.
Action: Replace the FRUs one at a time.
Go to "MAP 410: Repair Checkout" in
IBM
RS/6000 Diagnostic Information for
Multiple Bus Systems
to verify each
repair.
D0000 Disk drive module 100 Description: The using system cannot
configure the disk drive module. This is
probably a software problem.
Action:
1. Try again to configure the disk drive
module.
2. If the problem remains, go to
“Software and Microcode Errors” on
page A-5 before exchanging the FRU.
D0100 Disk drive module 100 Description: Unable to clear a disk drive
module reservation.
Action: Exchange the FRU for a new
FRU.
D0101 Disk drive module 100 Description: The disk drive module has
been reserved since the diagnostics
started. The disk drive module is in use.
Action: Release the disk drive module,
and run the diagnostics again.
A-12 Service Guide