5. Enter any requested passwords.
6. Wait until the diagnostics are loaded or the system appears to stop.
7. Find your symptom in the following table; then follow the instructions given in the
Action column.
Symptom Action
The diskette LED is blinking rapidly, or EIEA or
EIEB is displayed on the operator panel.
The flash EPROM data is corrupted. The
recovery procedure for the flash EPROM should
be executed. See “Firmware Recovery” on
page 5-23.
The system stops with a prompt to enter a
password.
Enter the password. You are not allowed to
continue until a correct password has been
entered. When you have entered a valid
password go to the beginning of this table and
wait for one of the other conditions to occur.
The diagnostics loaded. Go to MAP 0020 in the
IBM RS/6000 Diagnostic
Information for Multiple Bus Systems
.
The system login prompt is displayed. You may not have pressed the correct key or
you may not have pressed the key soon enough
when you were to indicate a Service Mode IPL
of the diagnostic programs. If this was the case
start over at the beginning of this Step.
Note: Perform the systems shutdown
procedure before turning off the system.
If you are sure you pressed the correct key in a
timely manner, go to “Step 1020-2” on
page 2-10.
The system does not respond when the
password is entered.
Go to “Step 1020-2” on page 2-10.
The system stopped and a POST indicator is
displayed on the system console and an
eight-digit error code is not displayed.
If the POST indicator represents:
memory, record error code M0MEM002.
keyboard, record error code M0KBD000.
SCSI, record error code M0CON000.
network, record error code M0NET000.
speaker (audio), record error code
M0BT0000.
Go to “Step 1020-3” on page 2-10.
2-8 Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 7025 F50 Series and is the answer not in the manual?

IBM RS/6000 7025 F50 Series Specifications

General IconGeneral
BrandIBM
ModelRS/6000 7025 F50 Series
CategoryServer
LanguageEnglish

Related product manuals