Table 3-1 (Page 6 of 24). Firmware Error Codes.
Error Code Description Action / Possible Failing FRU
21A00004 Send Diagnostic Failed - DevOfl cmd. Refer to the notes in error code
21A000xxx.
Replace the SCSI device.
21E00xxx SCSI Tape Refer to 21A00xxx for a description
and repair action for the xxx value.
21ED0xxx SCSI Changer. Refer to 21A00xxx for a description
and repair action for the xxx value.
21EE0xxx Other SCSI device type. Refer to 21A00xxx for a description
and repair action for the xxx value.
21F00xxx SCSI CD-ROM. Refer to 21A00xxx for a description
and repair action for the xxx value.
21F20xxx SCSI Read/Write Optical. Refer to 21A00xxx for a description
and repair action for the xxx value.
25000000 Memory Controller Failed. Replace the System Board.
25010xxx Flash Update Problem
25010000 No diskette in drive. Insert diskette containing firmware
image.
25010001 Diskette seek error. 1. Retry function.
2. Replace diskette drive.
3. Replace diskette cable.
4. Replace I/O board. (See notes on
3-1.)
25010002 Diskette in drive does not contain an
*.IMG file.
Insert diskette with firmware update file.
25010003 Cannot open OPENPROM package. Replace I/O board. (See notes on
3-1.)
25010004 Cannot find OPENPROM node. Replace I/O board. (See notes on
3-1.)
25010006 System id does not match image
system id.
Make sure correct firmware update
diskette is being used with this system.
25010007 Image has bad CRC. Replace firmware updated diskette.
25010008 Flash is write protected, update
cancelled.
1. Turn off, turn on system unit and
retry.
2. Replace I/O board. (See notes on
3-1.)
25010009 Flash module is unsupported or not
recognized.
Make sure correct firmware update
diskette is being used with this system.
2501000A Flash write protected. 1. Turn off, turn on system unit, retry.
2. Replace I/O board. (See notes on
3-1.)
Chapter 3. Error Code to FRU Index 3-7