Table 3-1 (Page 8 of 24). Firmware Error Codes.
Error Code Description Action / Possible Failing FRU
25A80100 NVRAM data validation check failed. Turn off, turn on system unit and retry
the operation before replacing any
system component. Refer to Action
under error code 25A80xxx.
25A80201 Unable to expand target partition while
saving configuration variable.
Refer to Action under error code
25A80xxx.
25A80202 Unable to expand target partition while
writing error log entry.
Refer to Action under error code
25A80xxx.
25A80203 Unable to expand target partition while
writing VPD data.
Refer to Action under error code
25A80xxx.
25A80210 Setenv/$Setenv parameter error - name
contains a null character.
Refer to Action under error code
25A80xxx.
25A80211 Setenv/$Setenv parameter error - value
contains a null character.
Refer to Action under error code
25A80xxx.
25AA0xxx EEPROM problems. EEPROM problem resolution:
1. Ensure that the EEPROM Security
jumper is in the correct position if
doing a privileged-access password
install.
2. Retry the operation.
3. If retries do not solve the problem,
replace the I/O board. (See notes
on 3-1.)
25AA0000 Unable to unlock EEPROM. Refer to Action under error code
25AA0xxx.
25AA0001 Read-Recv error. Refer to Action under error code
25AA0xxx.
25AA0002 Read-Trans error. Refer to Action under error code
25AA0xxx.
25AA0003 Write-enable error. Refer to Action under error code
25AA0xxx.
25AA0004 Write-recv error. Refer to Action under error code
25AA0xxx.
25AA0005 Write-disable error. Refer to Action under error code
25AA0xxx.
25AA0006 Write-Trans error. Refer to Action under error code
25AA0xxx.
25AA0007 Unable to lock EEPROM. Refer to Action under error code
25AA0xxx.
Chapter 3. Error Code to FRU Index 3-9