Table 3-1 (Page 14 of 24). Firmware Error Codes.
Error Code Description Action / Possible Failing FRU
2BA00200 Service processor firmware update
error occurred, update not completed.
Error occurred during service processor
flash write operation.
Service processor firmware update
error recovery procedure:
1. Turn the system Off.
2. Unplug power cable and then plug
power cable back in.
3. Turn the system On.
4. Retry operation. If problem
persists, replace service processor.
2BA00201 Service processor firmware update
error occurred, update not completed.
Error occurred while reading service
processor CRC.
See error code 2BA00200 for recovery
procedure.
2BA00202 Service processor firmware update
error occurred, update not completed.
Error occurred while verifying service
processor CRC.
See error code 2BA00200 for recovery
procedure.
2BA00203 Service processor firmware update
error occurred, update not completed.
Error occurred while reading new
service processor CRC after updating
service processor firmware.
See error code 2BA00200 for recovery
procedure.
2BA00204 Service processor firmware update
error occurred, update not completed.
Error occurred while calculate CRC
write.
See error code 2BA00200 for recovery
procedure.
2BA00300 Service Processor reports Slow Fan
number 1
1. Replace Fan 1.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
2BA00301 Service Processor reports Slow Fan
number 2.
1. Replace Fan 2.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
2BA00302 Service Processor reports Slow Fan
number 3.
1. Replace Fan 3.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
Chapter 3. Error Code to FRU Index 3-15