Table 3-1 (Page 13 of 24). Firmware Error Codes.
Error Code Description Action / Possible Failing FRU
2BA00051 System operator panel VPD data
corrupted.
Replace the operator panel control
assembly. (See notes on 3-1.)
Note: Swap the old VPD module from
the old operator panel control assembly
to the new one.
2BA00060 Service processor reports I/O board
VPD module not present.
Replace the I/O board. (See notes on
3-1.)
2BA00061 Service processor reports I/O board
VPD data corrupted.
Replace the I/O board. (See notes on
3-1.)
2BA00062 Service processor reports system board
VPD module not present.
Replace the system board.
2BA00063 Service processor reports system board
VPD data corrupted.
Replace the system board.
2BA00064 Service processor reports PCI riser
card VPD module not present.
Replace the PCI riser card.
2BA00065 Service processor reports PCI riser
card VPD data corrupted.
Replace the PCI riser card.
2BA00066 Service processor reports PCI
expansion card VPD module not
present.
Replace the PCI expansion card.
2BA00067 Service processor reports PCI
expansion card VPD data corrupted.
Replace the PCI expansion card.
2BA00070 Service processor reports CPU card
VPD module not present.
Replace the CPU card(s).
2BA00071 VPD data corrupted for CPU in slot 0. Replace the CPU card in slot 0.
2BA00073 VPD data corrupted for CPU in slot 1. Replace the CPU card in slot 1.
2BA00100 Service processor firmware recovery
information could not be written to
diskette.
1. Check diskette media write protect
tab.
2. Replace the diskette drive.
2BA00101 Service processor is not installed,
update cancelled.
1. Install the service processor.
2. Retry operation.
2BA00102 No service processor update diskette in
drive.
Insert the diskette.
2BA00103 Service processor firmware update file
is corrupted, update cancelled.
1. Obtain new service processor
firmware diskette.
2. Retry operation.
2BA00104 Service processor firmware update file
is the same level as the service
processor firmware, update cancelled.
1. Obtain new level of service
processor firmware.
2. Retry operation.
3-14 Service Guide