EasyManua.ls Logo

Icom IC-M804 - Other Functions

Icom IC-M804
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14

5
5
Other functions
Emergency FREQ channel


call can be monitored without receiving or transmitting
a DSC call.
1. 
Emergency FREQ
is displayed
in the Software Key area.
2. Push
Emergency FREQ
.

channel and
Emergency
is displayed in the Channel
area.
3. 
channel.
Noise Blanker function
The Noise Blanker function reduces pulse-type noises
that come from engine ignitions.
However, if the received strong signals are distorted,

1. 
NB
is displayed in the
Software Key area.
2. Push
NB

L 
Status area.
Noise Blanker Level

Noise Blanker level to reduce various pulse-type
noises.
Set to between 1 and 10.
1. 
NB Level
is displayed in the
Software Key area.
2. Push
NB Level
.
The NB level setting window is displayed.
3. 

Blanker level.
Squelch function
The Squelch function mutes unwanted signals such
as noise or unmodulated beat signals. This function
enables quiet standby.


1. 
SQL
is displayed in the
Software Key area.
2. Push
SQL

L 
Status area.
S-meter Squelch Level

stronger than this set level are received.
Set to between 0 (open) and 100 (tight).
1. 
S-SQL Level
is displayed in
the Software Key area.
2. Push
S-SQL Level
.

3. 
level.
RF gain Level



1. 
RF Gain
is displayed in the
Software Key area.
2. Push
RF Gain
.

3. 
Clarity Control function
With the Clarity Control function, you can slightly shift
the receive frequency without changing the operating


Set to between -150 Hz and +150 Hz (in 10 Hz steps).
1. 
Clarity
is displayed in the
Software Key area.
2. Push
Clarity

is displayed in the Channel area.
3. 
