IDS Base Station Receiver 400 700-179-02B Issued January 2009 29
4.
4.4.
4.
P
PP
Program
rogramrogram
rogram M
M M
Mode
odeode
ode
The program mode is the means for the user to setup the IDS Base Station Receiver to suit the user’s
system configuration.
NOTE:
The formats of the Program Mode displays are different between Base Control card version
V1.01 and lower and V1.02 upwards. The functions, however, are the same.
The order of the Firmware menu has changed and only appears once for version V1.02 and up.
The following program fields are not available on version V1.01 and lower.
• Event Date/Pre/Post
• Poll Date /Pre/Post
• LOAD DEFAULTS
Trouble Display
LINE CARD ABSENT
PRINTER ERROR
LINE TROUBLE
AE DTMF
Ademco Express
4/2 WP
FBI 4 by 2, With Parity
4/2 NP
FBI 4 by 2, No Parity
SESC SF
Sesco Superfast
SIA
Security Industry Association
Received record or parity error
MISSED CALL
No response to handshake
BSR detected TROUBLE Conditions
Or Restorals
Event Format Recieved From Alarm Panel
No Parity
1RRLssssssACCTsXssYY[DC4] - Basic Protocol
1RR0sssssssssss@ssss[DC4] - Hart Beat
5RRLs18AAAAQXYZGGCCC[DC4] - Contact ID
1RR0ssssss0000sXssYY[DC4] - Status Codes
4x2 Format
123456789ABCDEF
( X user chr)
See Table 1 Format Discription.
See 3.8.9 Basic Signal Protocol to 3.8.11