IDS Base Station Receiver 400 700-179-02B Issued January 2009 25
Table 1: FORMAT Description
1 CONT ID Contact ID
2 AE DTMF Ademco Express
3 4/2 WP FBI 4 by 2, With Parity
4 4/2 NP FBI 4 by 2, No Parity
5 SESC SF Sescoa Superfast
6 SIA Security Industry Association
7 4/1 4 by 1 Format
8 3/1 3 by 1 Format
9 ERROR Received record error
10 MISSED CALL No response to handshake
11 System MSG See Table 2: TROUBLE Conditions
12 ACKERR PC failed to Acknowledge Error
ERROR condition.
• The line card X detected a check sum error or the two records received for a dual reporting
format where not the same.
• The line card does not issue a “Kiss Off” to force the panel to resend the event record.
• The line card sends the received erroneous data to the control card and is displayed as
ACCTxxx…x on the bottom line of the display, see below. From version 3.06 and > a “Faulty
Data” system message, code 10, is sent to the monitoring program.
NOTE:
See 4.3.7 Format Options M107 to enable/disable this event from printing and outputting to the
monitoring program.
03 DEC 2000 16:48
LCx ERROR
ACCTxxx UVE
MISSED CALL.
• The indicated Line Card LCx detected a ring (dial in), picked up the line and transmitted the
handshake sequence.
• If no event record is received in response to the handshakes, the “Missed Call” error
message is displayed.
NOTE:
See 4.3.7 Format Options M107 to enable/disable this event being printed
03 DEC 2000 16:48
LCx
MISSED CALL
UVE
NOTE:
Subscribe to the Telkom “Call ID” see 3.3.8 General Installations Management
System MSG (Trouble)