IDS Base Station Receiver 400 700-179-02B Issued January 2009 36
massed passed on to the monitoring program and does cause incorrect responses when auditing the
printed output. This option enables or disables the event being printed and from version 3.06 the Missed
Call event is output to the monitoring program as a System Message, code 40, depending on the state of
this setting.
• 0 – Disables printing a missed call (default).
• 1 – Enables printing a missed call.
Enable/Disable Outputting Comms Absent/Restoral events
Reporting this to the PC is not possible when there is a breakdown in serial communication, thus the
output of this event may be disabled, and the default is enabled.
• 0 – Disables the output of a record with a detected error.
• 1 – Enables the output of a record with a detected error (default).
•
Enable/Disable resetting un-viewed events on a successful transfer of the events to the
“Monitoring Program”.
Reset un-viewed event to latest event, default, if “Monitoring Program” acknowledged receiving the event
or show number of un-viewed events on the base station control panel display.
The selection affects the panel display, printer output and serial output (Sout).
Format Option Display
1 2 3 4 5 6 7 8
Default Value 0 0 0 0 0 1 1 1
Table 4: Format out Options
Bit
BitBit
Bit
Function
FunctionFunction
Function
Def
DefDef
Def
1 Sescoa Superfast serial Event Code Identifier character (X) selection digit
0 - First digit (Default)
1 – Second
0
2 Contact ID qualifier format alpha or numeric
0 – Alpha (Default)
1 – Numeric
E -- 1 = New event or opening
R -- 3 = New restore or closing
P – 6 = Previous even
0
3 CID conversion of zero digit represented by “A” to “0”
0 – Convert “A” to “0” (Default).
1 – Digit un-altered
0
4 4x2 conversion of zero digit represented by “A” to “0”
0 – Digit un-altered (Default)
1 – Convert “A” to “0”
0
5 Disable/Enable Rx'ed ERROR events output.
0 – Disable serial and print output (Default).
1 – Enable serial and print output.
0
6 Disable/Enable Rx'ed Missed Calls printing.
0 – Disable serial and print output.
1 – Enable serial and print output (Default).
1
7 Disable/Enable Comms Absent/Restoral output.
0 – Disable serial and print output.
1