Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Readi
ng Type
Event Offset Triggers Contrib. To
System Status
Assert/
De-
assert
Readable
Value/Of
fsets
Event
Data
Rearm
Stand-
by
IO Module Presence
(IO Mod Presence)
0Eh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 – Inserted/Present OK
As
and
De
– Trig Offset M -
SAS Module Presence
(SAS Mod Presence)
0Fh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 – Inserted/Present OK
As
and
De
– Trig Offset M X
BMC Firmware Health
(BMC FW Health)
10h All
Mgmt Health
28h
Sensor
Specific
6Fh
04 – Sensor Failure
Degraded
As - Trig Offset A X
System Airflow
(System Airflow)
11h All
Other Units
0Bh
Threshold
01h
– – Analog
FW Update Status 12h All Version Change
2Bh
OEM
defined
x70h
00hUpdate started
01hUpdate
completed
successfully.
02hUpdate failure
OK As _ Trig Offset A _
IO Module2 Presence
(IO Mod2 Presence)
13h
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 – Inserted/Present OK
As
and
De
– Trig Offset M -
Baseboard Temperature 5
(Platform Specific)
14h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A X
Baseboard Temperature 6
(Platform Specific)
15h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A X
IO Module2 Temperature
(I/O Mod2 Temp)
16h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A X